<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://mediawiki.comfac.net/index.php?action=history&amp;feed=atom&amp;title=Power_Distribution_Tree_251213</id>
	<title>Power Distribution Tree 251213 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://mediawiki.comfac.net/index.php?action=history&amp;feed=atom&amp;title=Power_Distribution_Tree_251213"/>
	<link rel="alternate" type="text/html" href="https://mediawiki.comfac.net/index.php?title=Power_Distribution_Tree_251213&amp;action=history"/>
	<updated>2026-06-05T09:48:01Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.45.1</generator>
	<entry>
		<id>https://mediawiki.comfac.net/index.php?title=Power_Distribution_Tree_251213&amp;diff=68&amp;oldid=prev</id>
		<title>CITEditor: Created page with &quot;= Power Distribution &amp; IoT Strategy: The Tree of Power =  &#039;&#039;&#039;Document ID:&#039;&#039;&#039; 251213-PDT&lt;br&gt; &#039;&#039;&#039;Last Updated:&#039;&#039;&#039; December 13, 2025&lt;br&gt; &#039;&#039;&#039;Category:&#039;&#039;&#039; Facility Infrastructure &amp; IoT Strategy  == Power Distribution Overview ==  &lt;pre&gt; Utility Grid / Service Entrance       │       ├── Step-Down Transformer (e.g., 13.8kV → 480V)       │       ├── Main Switchgear / Main Distribution Panel (MDP)       │         │       │         ├── ATS (for generat...&quot;</title>
		<link rel="alternate" type="text/html" href="https://mediawiki.comfac.net/index.php?title=Power_Distribution_Tree_251213&amp;diff=68&amp;oldid=prev"/>
		<updated>2026-02-25T07:17:40Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;= Power Distribution &amp;amp; IoT Strategy: The Tree of Power =  &amp;#039;&amp;#039;&amp;#039;Document ID:&amp;#039;&amp;#039;&amp;#039; 251213-PDT&amp;lt;br&amp;gt; &amp;#039;&amp;#039;&amp;#039;Last Updated:&amp;#039;&amp;#039;&amp;#039; December 13, 2025&amp;lt;br&amp;gt; &amp;#039;&amp;#039;&amp;#039;Category:&amp;#039;&amp;#039;&amp;#039; Facility Infrastructure &amp;amp; IoT Strategy  == Power Distribution Overview ==  &amp;lt;pre&amp;gt; Utility Grid / Service Entrance       │       ├── Step-Down Transformer (e.g., 13.8kV → 480V)       │       ├── Main Switchgear / Main Distribution Panel (MDP)       │         │       │         ├── ATS (for generat...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;= Power Distribution &amp;amp; IoT Strategy: The Tree of Power =&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Document ID:&amp;#039;&amp;#039;&amp;#039; 251213-PDT&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Last Updated:&amp;#039;&amp;#039;&amp;#039; December 13, 2025&amp;lt;br&amp;gt;&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Category:&amp;#039;&amp;#039;&amp;#039; Facility Infrastructure &amp;amp; IoT Strategy&lt;br /&gt;
&lt;br /&gt;
== Power Distribution Overview ==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Utility Grid / Service Entrance&lt;br /&gt;
      │&lt;br /&gt;
      ├── Step-Down Transformer (e.g., 13.8kV → 480V)&lt;br /&gt;
      │&lt;br /&gt;
      ├── Main Switchgear / Main Distribution Panel (MDP)&lt;br /&gt;
      │         │&lt;br /&gt;
      │         ├── ATS (for generator backup)&lt;br /&gt;
      │         └── Busbars&lt;br /&gt;
      │&lt;br /&gt;
      ├── Sub-Distribution Panels (SDPs) / Switchboards&lt;br /&gt;
      │         │&lt;br /&gt;
      │         ├── Motor Control Centers (MCC)&lt;br /&gt;
      │         │&lt;br /&gt;
      │         ├── Distribution Boards (DBs)&lt;br /&gt;
      │         │&lt;br /&gt;
      │         └── Local Panels&lt;br /&gt;
      │&lt;br /&gt;
      └── Loads (Lighting, HVAC, Motors, Servers, Sockets, Specialty)&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== 1. Overview: The Tree Analogy ==&lt;br /&gt;
&lt;br /&gt;
To understand our facility&amp;#039;s power infrastructure and where our analysis products fit, we use the &amp;#039;&amp;#039;&amp;#039;&amp;quot;Tree of Power&amp;quot;&amp;#039;&amp;#039;&amp;#039; analogy. Electricity flows from the &amp;quot;Roots&amp;quot; (Utility) up through the &amp;quot;Trunk&amp;quot; (Main Panels) and out to the &amp;quot;Leaves&amp;quot; (Individual Machines).&lt;br /&gt;
&lt;br /&gt;
Effective energy management requires monitoring at different levels of this tree. While traditional BMS (Building Management Systems) focus on the Trunk and Branches, our &amp;#039;&amp;#039;&amp;#039;QMT Edge Devices&amp;#039;&amp;#039;&amp;#039; focus on the Twigs and Leaves, where granular operational data lives.&lt;br /&gt;
&lt;br /&gt;
== 2. Facility Structure &amp;amp; Hardware ==&lt;br /&gt;
&lt;br /&gt;
=== Level 1: The Roots (Utility Connection) ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;What it is:&amp;#039;&amp;#039;&amp;#039; The point where raw power enters our facility from the grid (e.g., Meralco) or onsite generators.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Facility Equipment:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;HV Switchgear:&amp;#039;&amp;#039;&amp;#039; High voltage protection.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Step-Down Transformer:&amp;#039;&amp;#039;&amp;#039; Converts 13.8kV/34.5kV → 400V/230V.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Function:&amp;#039;&amp;#039;&amp;#039; Provides the raw energy flow for the entire site.&lt;br /&gt;
&lt;br /&gt;
=== Level 2: The Trunk (Main Distribution) ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;What it is:&amp;#039;&amp;#039;&amp;#039; The central artery of power distribution.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Facility Equipment:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;MDP (Main Distribution Panel):&amp;#039;&amp;#039;&amp;#039; The massive main breaker cabinet (2000A - 4000A capacity).&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Automatic Transfer Switch (ATS):&amp;#039;&amp;#039;&amp;#039; Switches between Grid and Generator.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Function:&amp;#039;&amp;#039;&amp;#039; Protects the main facility feeder. A failure here causes a total site blackout.&lt;br /&gt;
&lt;br /&gt;
=== Level 3: The Big Branches (Zonal Distribution) ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;What it is:&amp;#039;&amp;#039;&amp;#039; The division of power into major zones (e.g., &amp;quot;West Wing,&amp;quot; &amp;quot;Production Line A,&amp;quot; &amp;quot;Chiller Plant&amp;quot;).&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Facility Equipment:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;SDP (Sub-Distribution Panel):&amp;#039;&amp;#039;&amp;#039; Feeds a specific floor or department.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;MCC (Motor Control Center):&amp;#039;&amp;#039;&amp;#039; A specialized row of cabinets dedicated entirely to controlling heavy industrial motors (pumps, fans, conveyors).&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Function:&amp;#039;&amp;#039;&amp;#039; Distributes power to specific physical areas or high-load groups.&lt;br /&gt;
&lt;br /&gt;
=== Level 4: The Twigs (Final Circuits) ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;What it is:&amp;#039;&amp;#039;&amp;#039; The final &amp;quot;last mile&amp;quot; wiring before the machine.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Facility Equipment:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;DB (Distribution Board / Load Center):&amp;#039;&amp;#039;&amp;#039; The wall-mounted breaker box containing 15A-60A breakers.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Local Control Panel:&amp;#039;&amp;#039;&amp;#039; The small box right next to a machine containing relays and start/stop buttons.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Function:&amp;#039;&amp;#039;&amp;#039; Protects the specific wire going to a specific machine.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Strategic Importance:&amp;#039;&amp;#039;&amp;#039; This is the ideal installation point for &amp;#039;&amp;#039;&amp;#039;Edge Analytics&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
=== Level 5: The Leaves (The Loads) ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;What it is:&amp;#039;&amp;#039;&amp;#039; The actual equipment performing work.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Facility Equipment:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Inductive Loads:&amp;#039;&amp;#039;&amp;#039; Motors, Compressors, Pumps.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Resistive Loads:&amp;#039;&amp;#039;&amp;#039; Heaters, Ovens.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;IT Loads:&amp;#039;&amp;#039;&amp;#039; Server racks, Workstations.&lt;br /&gt;
&lt;br /&gt;
== 3. Monitoring &amp;amp; BMS Ecosystem ==&lt;br /&gt;
&lt;br /&gt;
The &amp;quot;Gap&amp;quot; in the market is at Levels 4 and 5. Traditional systems monitor the &amp;#039;&amp;#039;quantity&amp;#039;&amp;#039; of power at the top, but our devices monitor the &amp;#039;&amp;#039;quality and health&amp;#039;&amp;#039; of the machine at the bottom.&lt;br /&gt;
&lt;br /&gt;
=== A. Central Management (Levels 1 &amp;amp; 2) ===&lt;br /&gt;
&lt;br /&gt;
At the Trunk, we use &amp;#039;&amp;#039;&amp;#039;Power Quality Analyzers (PQAs)&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Device Type:&amp;#039;&amp;#039;&amp;#039; Class A Meter (e.g., Schneider PM8000).&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Data:&amp;#039;&amp;#039;&amp;#039; Total kWh, Power Factor, Harmonics (THD), Voltage Sags/Swells.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Goal:&amp;#039;&amp;#039;&amp;#039; Billing verification and total plant efficiency.&lt;br /&gt;
&lt;br /&gt;
=== B. Automation Level (Level 3) ===&lt;br /&gt;
&lt;br /&gt;
At the MCC/SDP, we use &amp;#039;&amp;#039;&amp;#039;PLCs and Digital Meters&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Device Type:&amp;#039;&amp;#039;&amp;#039; Industrial PLC (Siemens/Allen-Bradley) or Mid-range Meters.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Data:&amp;#039;&amp;#039;&amp;#039; On/Off status, Amps per phase.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Goal:&amp;#039;&amp;#039;&amp;#039; Process automation (turning things on/off) and departmental costing.&lt;br /&gt;
&lt;br /&gt;
=== C. Edge Analysis Level (Level 4 &amp;amp; 5 - Our Layer) ===&lt;br /&gt;
&lt;br /&gt;
This is where our &amp;#039;&amp;#039;&amp;#039;Custom ESP32 Controller&amp;#039;&amp;#039;&amp;#039; sits.&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Device Type:&amp;#039;&amp;#039;&amp;#039; &amp;#039;&amp;#039;&amp;#039;Smart DIN Rail Relay + Edge Analyzer&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Location:&amp;#039;&amp;#039;&amp;#039; Inside the DB or Local Control Panel (The &amp;quot;Twig&amp;quot;).&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Unique Capabilities:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;High-Frequency Sampling:&amp;#039;&amp;#039;&amp;#039; Unlike a standard meter that reports 1 data point per second, our device samples current at 10kHz+.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;FFT Analysis:&amp;#039;&amp;#039;&amp;#039; Performs Fourier Transform on-chip to detect &amp;quot;Motor Signature&amp;quot; anomalies (bearing faults, rotor bar issues) before the machine fails.&lt;br /&gt;
** &amp;#039;&amp;#039;&amp;#039;Action:&amp;#039;&amp;#039;&amp;#039; Can physically cut power (Relay) if a safety threshold is breached.&lt;br /&gt;
&lt;br /&gt;
== Device Integration Diagram ==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
 [A] ROOT: UTILITY SERVICE (Meralco)&lt;br /&gt;
  │&lt;br /&gt;
  │   Warning: No physical connection allowed to utility meter/cables.&lt;br /&gt;
  │   Demarcation Point: The Service Entrance / Main Breaker Line Side.&lt;br /&gt;
  │&lt;br /&gt;
  ├── [A1] Meralco Meter (Revenue Meter)&lt;br /&gt;
  │       └── Non-Intrusive Monitoring (Optical/Pulse)&lt;br /&gt;
  │&lt;br /&gt;
  ▼&lt;br /&gt;
 [B] TRUNK: MAIN DISTRIBUTION&lt;br /&gt;
  │&lt;br /&gt;
  ├── [B1] Main Switchgear / MDP (Main Distribution Panel)&lt;br /&gt;
  │       │&lt;br /&gt;
  │       ├── Main Breaker (ACB/MCCB)&lt;br /&gt;
  │       ├── [B2] Power Quality Analyzer (PQA)&lt;br /&gt;
  │       └── [B3] IoT Gateway / Edge Controller&lt;br /&gt;
  │&lt;br /&gt;
  ├── [B4] Automatic Transfer Switch (ATS)&lt;br /&gt;
  │       └── Generator / Backup Feed&lt;br /&gt;
  │&lt;br /&gt;
  ▼&lt;br /&gt;
 [C] BRANCHES: SUB-DISTRIBUTION&lt;br /&gt;
  │&lt;br /&gt;
  ├── [C1] Sub-Distribution Panels (SDP)&lt;br /&gt;
  │       │&lt;br /&gt;
  │       ├── [C2] Branch Circuit Monitoring System (BCMS)&lt;br /&gt;
  │       └── [C3] Smart Breakers&lt;br /&gt;
  │&lt;br /&gt;
  ├── [C4] Motor Control Center (MCC)&lt;br /&gt;
  │       └── [C5] Variable Frequency Drives (VFDs)&lt;br /&gt;
  │&lt;br /&gt;
  ▼&lt;br /&gt;
 [D] LEAVES: DEVICES &amp;amp; LOADS&lt;br /&gt;
  │&lt;br /&gt;
  ├── [D1] Smart Power Supply Units (PSUs)&lt;br /&gt;
  │       └── 24V DC Systems (PLC, Controls, LED Strips)&lt;br /&gt;
  │&lt;br /&gt;
  ├── [D2] Lighting Loads&lt;br /&gt;
  │       └── DALI / Smart Drivers&lt;br /&gt;
  │&lt;br /&gt;
  └── [D3] Plug Loads &amp;amp; Appliances&lt;br /&gt;
          └── Smart Sockets / Inline Modules&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Device Specification Tables ===&lt;br /&gt;
&lt;br /&gt;
==== [A] ROOT: Utility (Meralco Meter) ====&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;Constraint: No physical contact allowed.&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! ID !! Device Type !! Specific Tech / Protocol !! Description&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[A1]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Optical Probe&amp;#039;&amp;#039;&amp;#039; || IEC 62056-21 Probe || Magnetic &amp;quot;eye&amp;quot; that attaches to the meter&amp;#039;s optical port to read digital data.&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[A1]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Pulse Counter&amp;#039;&amp;#039;&amp;#039; || Photodiode Sensor || Sensor taped over the flashing LED (imp/kWh) to count usage pulses.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== [B] TRUNK: Main Distribution (MDP) ====&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;Goal: High-accuracy monitoring and Power Quality.&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! ID !! Device Type !! Recommended Spec !! Functions&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[B2]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Power Meter&amp;#039;&amp;#039;&amp;#039; || Schneider PM8000 / Janitza UMG || Class 0.2S Accuracy. Measures Harmonics (THD), Sags, Swells.&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[B3]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;IoT Gateway&amp;#039;&amp;#039;&amp;#039; || Ind. Raspberry Pi / Teltonika || Aggregates Modbus/TCP data and sends to Cloud/Local Dashboard.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== [C] BRANCHES: Sub-Distribution ====&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;Goal: Granular breakdown (Departmental metering).&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! ID !! Device Type !! Recommended Spec !! Functions&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[C2]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;BCMS Strip&amp;#039;&amp;#039;&amp;#039; || Solid-Core CT Strip || Monitors 12-42 breaker poles simultaneously via one module.&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[C5]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;VFD / VSD&amp;#039;&amp;#039;&amp;#039; || Danfoss / Yaskawa || Connected via Modbus/RS485 to report RPM, Torque, and Energy.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==== [D] LEAVES: Special Focus on PSUs &amp;amp; ESP32 ====&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;Goal: Monitoring low-voltage DC loads and individual appliances.&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! ID !! Device Category !! Implementation Solution&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[D1]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Smart PSU&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Add-on Module:&amp;#039;&amp;#039;&amp;#039; Use standard Mean Well PSU + &amp;#039;&amp;#039;&amp;#039;INA226&amp;#039;&amp;#039;&amp;#039; sensor module + &amp;#039;&amp;#039;&amp;#039;ESP32-C3&amp;#039;&amp;#039;&amp;#039; on DIN rail.&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[D3]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Smart Plug&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Shelly Plus Plug S&amp;#039;&amp;#039;&amp;#039; (ESP32-based) for socket loads.&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;[D3]&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Inline Module&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;Sonoff POW Elite&amp;#039;&amp;#039;&amp;#039; (ESP32-based) for installation inside junction boxes.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== 4. Summary Table: The Tree of Power ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Tree Level !! Facility Infrastructure !! Primary Voltage/Current !! Monitoring System (Standard) !! Our Solution (QMT Edge)&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;1. Roots&amp;#039;&amp;#039;&amp;#039; || Transformer / HV Switchgear || 13.8kV+ || Utility Metering (Billing) || &amp;#039;&amp;#039;N/A (Too high voltage)&amp;#039;&amp;#039;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;2. Trunk&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;MDP&amp;#039;&amp;#039;&amp;#039; (Main Dist. Panel) || 400V / 2000A+ || &amp;#039;&amp;#039;&amp;#039;SCADA / PQA&amp;#039;&amp;#039;&amp;#039; (Total Plant Power Quality) || &amp;#039;&amp;#039;N/A&amp;#039;&amp;#039;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;3. Branches&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;MCC&amp;#039;&amp;#039;&amp;#039; (Motor Control Center) / &amp;#039;&amp;#039;&amp;#039;SDP&amp;#039;&amp;#039;&amp;#039; (Sub-Panel) || 400V / 200A - 800A || &amp;#039;&amp;#039;&amp;#039;BMS / PLC&amp;#039;&amp;#039;&amp;#039; (Status: On/Off, Amps) || &amp;#039;&amp;#039;N/A&amp;#039;&amp;#039;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;4. Twigs&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;DB&amp;#039;&amp;#039;&amp;#039; (Distribution Board) / &amp;#039;&amp;#039;&amp;#039;Local Control Panel&amp;#039;&amp;#039;&amp;#039; || 230V / 10A - 60A || &amp;#039;&amp;#039;&amp;#039;Dumb Breakers&amp;#039;&amp;#039;&amp;#039; (No data, just protection) || &amp;#039;&amp;#039;&amp;#039;TARGET ZONE&amp;#039;&amp;#039;&amp;#039; — Integrated Relay + Current Analysis&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;&amp;#039;5. Leaves&amp;#039;&amp;#039;&amp;#039; || &amp;#039;&amp;#039;&amp;#039;The Load&amp;#039;&amp;#039;&amp;#039; (Motors, Pumps, Heaters) || Utilization Voltage || &amp;#039;&amp;#039;&amp;#039;Physical Sensors&amp;#039;&amp;#039;&amp;#039; (Vibration, Temp probes) || &amp;#039;&amp;#039;&amp;#039;Virtual Sensors&amp;#039;&amp;#039;&amp;#039; (Motor Health inferred from Current)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[Category:STEWARD]]&lt;br /&gt;
[[Category:IoT]]&lt;br /&gt;
[[Category:Infrastructure]]&lt;br /&gt;
[[Category:Comfac]]&lt;/div&gt;</summary>